CompactPCI Power Backplanes
Hartmann offers a wide selection of CompactPCI power backplanes designed according to the PICMG 2.0 Power supply unit connector pin assignment specification/ATX power supply specification, or PICMG 2.11 Power Interface Specification and are equipped with the P47 power plug-in connector.
Specifications:
-
Designed for either power supply with DIN 41612 type M, or P47 plug-in connector
-
Possible slot quantity: 1, 2, 3, 4, 1-8 slots
-
3 and 6U versions
-
Supports parallel connection of multiple backplanes
-
With and without software for error identification
|
Variant |
Height |
Product Overview |
Slot |
Order |
Add’l Description |
| R0 | 3U | For power supply with DIN41612 type M connector. Current supply through DIN 41612 type M connector |
1 | 33R0000013 | Pin A1 facing down |
| L0 | 3U | For power supply with DIN41612 type M connector. Current supply through DIN 41612 type M connector |
1 | 33L0000014 | Pin A1 facing up |
| L1 Professional | 3U | For power supply with P47 connector. Current supply through 3-pin MATE-N-LOK connector. Supports parallel connection of multiple backplanes | 1 - 8 | 33L10000_4 | J1 closed |
| 33L10000_5 | J1 open | ||||
| L1 Standard | 3U | For power supply with P47 connector. Current supply through 3-pin MATE-N-LOK connector. Cost-effective alternative to L1 Professional when multiple backplanes to be connected simultaneously |
1 | 33L1000004 | J1 closed |
| 33L1000005 | J1 open | ||||
| L2 | 3U | For power supply with P47 connector. Current supply through 6-pin MATE-N-LOK connector. Monolithic as a cost-effective alternative to L1 Professional when multiple backplanes to be connected simultaneously |
2 | 33L2000014 | |
| L4 Professional | 3U | For power supply with P47 connector. Current supply through P47 connector. With software for error identification in power supply units |
3 | 33L0030014 | |
| 4 | 33L0040014 | ||||
| L4 Eco | 3U | For power supply with P47 connector. Current supply through P47 connector. Monolithic as a cost-effective alternative to version L1 professional without error identification |
4 | 33L0030024 | |
| 4 | 33L0040024 | ||||
| L1 Professional | 6U | For power supply with P47 connector. Current supply through P47 connector. Supports parallel connection of multiple backplanes |
1 - 8 | 36L10000_4 | J1 closed |
| 36L10000_5 | J1 open | ||||
| L1 Standard | 6U | For power supply with P47 connector. Current supply through P47 connector. Cost-effective alternative to L1 Professional when multiple backplanes to be connected simultaneously |
1 | 36L1000004 | J1 closed |
| 36L1000005 | J1 open |